Presentasjon lastes. Vennligst vent

Presentasjon lastes. Vennligst vent

NOVECTM 1230 NORTRONIK AS The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto).

Liknende presentasjoner


Presentasjon om: "NOVECTM 1230 NORTRONIK AS The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto)."— Utskrift av presentasjonen:

1 NOVECTM 1230 NORTRONIK AS The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto). A few of the niche application chemical agents can claim some benefits but cannot combine - human safety (suitable for use in occupied areas) with a clean environmental profile.

2 Supplerende til eksisterende gassprodukter som f.eks. Inergen og CO2
NOVECTM 1230 NOVECTM 1230 gir store muligheter fordi den har en unik kombinasjon av egenskaper for en kjemisk gass. Gassen er utviklet av 3M og Tyco har laget system løsningen. Ufarlig for mennesker - kan brukes i bemannede rom Ingen ozon skadende egenskaper Ingen drivhus effekt Inneholder hverken brom eller klor Utmerket brannslokke evne Kompakt lagring Enkel refylling Supplerende til eksisterende gassprodukter som f.eks. Inergen og CO2 The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto). A few of the niche application chemical agents can claim some benefits but cannot combine - human safety (suitable for use in occupied areas) with a clean environmental profile.

3 NOVECTM 1230 Dodecafluoro-2-methylpentan-3-one Fluor Oksygen
Fluorisert keton – sikker og effektiv brannslokke ytelse uten noen miljømessige ulemper – en kombinasjon av egenskaper som gjør den unik blant kjemiske slokke midler Fluor Oksygen Karbon The molecule has only just been announced and has taken everyone by surprise with many believing that a class of ketones could not be produced that would not be flammable or have human toxicity concerns. Some other agents are being developed but their properties and costs are still not known (expected to be high) and may still be a year or so away from commercialisation.

4 NOVECTM 1230 Noen fakta Slokker gjennom en kombinasjon av varme absorbering (kjøling er hovedeffekten) og direkte kjemisk inngrep med flammen Fortrenger ikke oksygen Utløsetiden er 10 sekunder Væske som omdannes til gass Lavt trykk på sylinderen – 25 bar Ikke behov for trykkavlastning Kan brukes til både system- og punktslokking The molecule has only just been announced and has taken everyone by surprise with many believing that a class of ketones could not be produced that would not be flammable or have human toxicity concerns. Some other agents are being developed but their properties and costs are still not known (expected to be high) and may still be a year or so away from commercialisation.

5 NOVECTM 1230 Miljøpåvirkning sammenlignet med andre slokkesystemer
Type O.D.P. G.W.P A.T.L. Halon – ~ 65 år FM ,5 år HFC ,6 år FE år Inergen® < 1 anvendes ikke NovecTM ~ 5 dager ODP = Ozone depletion potential (CFC 11 = 1) GWP = Global Warming Potensial (CO2 = 1) ATL = Atmospheric lifetime Det første kjemiske slokkemiddelet aksepert brukt i bemannede rom The search for the environmentally acceptable ‘in kind’ halon alternative has been on since concerns over halon become known. All HFC’s and PFC’s have high global warming potential which in fairness is less of an issue in the US and other parts of the world - but is becoming a major politically issue in Europe. For info. The difference between this slide and the next is this one covers total flooding applications (such as those protected by halon 1301), whereas the next covers the streaming applications (such as those protected by halon 1211 in portables) The first series of testing that I did with 3M concentrated on turning a natural streaming agent (a liquid) into a gas. We have been successful in doing this but still have work to do and will be working further on this during the next series of tests.

6 Sikkerhets faktorer - Class B hazard (brennbare væsker) marine
NOVECTM 1230 Sikkerhets faktorer - Class B hazard (brennbare væsker) marine Slokke konsentrasjon NOAEL* Sikkerhetsmargin Halon % % null FM % % % HFC ,5% ,5% negativ NAF III S ,9% % negativ Inergen® % % % - 13% CO % < 5% dødelig ved design konsentrasjon NovecTM ,5% % % *No Observable Adverse Effect Level (ingen merkbar negativ effekt) Har overlegent bedre marginer for menneskelig sikkerhet sammenlignet med halon og alle mulige alternativer Inert gases as well as FM200 are considered as safe for use in occupied areas. One area in particular where there exists a huge market potential is in Marine applications. Still the most common halon alternative is CO2 - due to it’s cost advantages over the other alternatives but it kills people and therefore where the owner is more concerned about his crew than the cost, most opt for FM200 because of its significant weight and space advantages over the inerts. But there is reluctance to use FM200 in Marine systems for two primary reasons 1. Fears that it may become the next halon and get banned eventually 2. At diesel fuel extinguishing/design concentrations (8.7%) safety margins are seriously eroded - this was the main justification for our previous excursions with the previous ultra safe 3M products.

7 NOVECTM 1230 Plass og vekt hensyn Ant. sylindere* Ant. sylindere**
Halon FM NovecTM CO Inergen® (200 bar) Inergen® (300 bar) Romstørrelse 500 m3 : *Class A hazard (datarom, el-tavler) **Class B hazard (brennbare væsker) Plass og vekt fordeler sammenlignet med Inergen og CO2 It is one of the major plus points for chemical agents that they offer compact storage - one of the main drawbacks associated with the inerts. Whilst we still have testing to do that will confirm exact quantities of agent required the first signs are that it will be similar to FM200 - the most popular halon alternative in the world. We will need to work to get appropriate design concentrations to keep costs comparable with FM200. The next series of tests (I am scheduled to go to 3M w/c 11th June), will allow us to establish class A concentrations which are expected to make the weight comparison similar to FM200

8 For marine anlegg leveres følgende sylinder størrelser
NOVECTM 1230 For marine anlegg leveres følgende sylinder størrelser Sylindervolum Total Maks 1) Omtrentlig rom volum i m3 i liter Diameter høyde totalvekt Min 8 254 389 27 5 12 16 588 39 10 24 32 920 66 20 47 52 406 726 110 77 106 1151 205 65 157 147 1484 273 91 218 180 1763 330 111 267 343 210 476 1) Beregnet ut fra DNV regler: design temp 20 ºC og min/maks fylling 0,5/1,2 kg pr. liter

9 NOVECTM 1230 NOVECTM 1230 er lagret som væske og trykksettes med Nitrogen (som halon 1301) Kokepunkt 48 ºC (halon: -57,8 ºC) Ubetydelig fordampnings trykk som gjør det - lett å transportere (ikke trykksatt) - lett å fylle (ingen fyllestasjon er nødvendig) Refylling kan gjøres ombord Ingen restriksjoner på transport (ikke trykksatt) The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto). A few of the niche application chemical agents can claim some benefits but cannot combine - human safety (suitable for use in occupied areas) with a clean environmental profile.

10 NOVECTM 1230 Til bruk ombord i skip har Novec™ systemene blitt utviklet som et sikkert alternativ til CO2 og FM 200 m.fl. Du har et valg: Sikkerhet, Miljø, Plassbehov og Vekt Eksisterende utløsersystem kan i de aller fleste tilfeller benyttes om igjen (elektrisk, pneumatisk eller wiretrekk) Vi forestår design og godkjennelse av anlegget Viktig med riktig volumberegning! Plassering av sylindere i maskinrom krever spesielle hensyn

11 NOVECTM 1230 Marine godkjennelser Det Norske Veritas (DNV)
Lloyds Register of Shipping MCA (Marine & Coastguard Agency) Bureau Veritas RINA (Registro Italiano Navale) Icelandic Maritime Administration NSI BZI DMA LRS MED Marchant Marine ABS og Germanischer Lloyd underveis The key things here are that this product is exempt from either the Montreal Protocol and the Climate Change Convention (Kyoto). A few of the niche application chemical agents can claim some benefits but cannot combine - human safety (suitable for use in occupied areas) with a clean environmental profile.

12 Neste generasjon av kjemiske slokkemidler
NOVECTM 1230 Neste generasjon av kjemiske slokkemidler Sikker for mennesker: – opp til nesten 100% sikkerhetsmargin Miljøvennlig: ODP = 0 GWP = 1 ATL = 3 til 5 dager Kompakt lagring og lavt trykk Enkel refylling SNAP listing (liste over godkjente halon alternativer) Key Points A few of the niche application chemical agents can claim some benefits but cannot combine - human safety (suitable for use in occupied areas) with a clean environmental profile. 1. Safe for people- low design design concentration compared to NOAEL. Higher safety factor than any other viable agent - inert gas or halocarbon 2. ODP of zero and GWP of one, make this agent exempt from Montreal Protocol and the Kyoto Climate Change Convention. 3. Short enviuronmental lifetime giving this truly long term sustainability. 4. Compact storage - offering the benefits of other chemical agents like halon, FM200 but without the perceived environmental threat 5. UL listing process underway and Marine testing scheduled in time for FP46. US EPA SNAP approval in place. 6. System costs comparable with existing halon alternatives. 7. Availability scheduled for January 2002, 8. To be offered as a complimentary gaseous product. For example not as a competitor to Inergen but as enabling Tyco contracting business to offer a complete range of technologies